Chapter 1
Alarm Troubleshooting
Performing a loopback on an in-service circuit is Service-Affecting (SA). If you did not perform a
Note
lockout or Force switch to protect traffic, the LPBKTERMINAL condition can also be accompanied by
a more serious alarm such as LOS.
For information about troubleshooting electrical circuits with loopbacks, refer to the
Points of Failure on an Electrical Circuit Path" section on page
"1.3 Identify Points of Failure on an OC-N Circuit Path" section on page
described in the
Clear the LPBKTERMINAL (OCN) Condition
Step 1
Complete the
If the condition does not clear, log into the Technical Support Website at
Step 2
http://www.cisco.com/techsupport for more information or call Cisco TAC (1 800 553-2447).
1.7.163 LWBATVG
The Low Voltage Battery alarm occurs in a –48 VDC environment for an ONS 15310-CL when a battery
lead input voltage falls below the low power threshold. This threshold has a preset value of –44 VDC
and is not user-provisionable. The alarm remains raised until the voltage remains above the threshold for
120 seconds. (For information about changing this threshold, refer to the "Turn Up Node" chapter in the
Cisco ONS 15310-CL and Cisco ONS 15310-MA Procedure Guide.)
Clear the LWBATVG Alarm
The problem is external to the ONS 15310-CL. Troubleshoot the power source supplying the battery
Step 1
leads.
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
Step 2
for more information or call Cisco TAC (1 800 553-2447) in order to report a Service-Affecting (SA)
problem.
1.7.164 MAN-REQ
The Manual Switch Request condition occurs when a user initiates a Manual switch request on an OC-N
port. Clearing the Manual switch clears the MAN-REQ condition. You do not need to clear the switch if
you want the manual switch to remain.
78-17235-01
"1.1.2 Terminal Loopback" section on page
"Clear an OC-N Port Facility or Terminal Loopback Circuit" procedure on page
Default Severity: Major (MJ), Service-Affecting (SA)
SONET Logical Object: PWR
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Objects: STSMON, VT-MON
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
1.7.163 LWBATVG
"1.2 Identify
1-3; for optical circuits, refer to the
1-13. Terminal loopbacks are
1-3.
1-157.
1-107