1.7.42 CONTBUS-DISABLED

1.7.42 CONTBUS-DISABLED
The CONTBUS-DISABLED alarm occurs when an Ethernet card is defective upon insertion into the
chassis or when a card that is already present in the chassis becomes defective. (That is, the card fails
the enhanced cell bus verification test.) The alarm persists as long as the defective card remains in the
chassis. When the card is removed, CONTBUS-DISABLED will remain raised for a one-minute wait
time. This wait time is designed as a guard period so that the system can distinguish this outage from a
briefer card reset communication outage.
If no card is reinserted into the original slot during the wait time, the alarm clears. After this time, a
different, nondefective card (not the original card) should be inserted.
When CONTBUS-DISABLED is raised, no message-oriented communication is allowed to or from this
Ethernet slot to the controller card (15310-CL-CTX or CTX2500), thus avoiding node communication
failure.
CONTBUS-DISABLED clears only when the faulty card is removed for one minute. If any card at all is
Caution
reinserted before the one-minute guard period expires, the alarm does not clear.
CONTBUS-DISABLED overrides the IMPROPRMVL alarm during the one-minute wait period, but
afterward IMPROPRMVL can be raised because it is no longer suppressed. IMPROPRMVL is raised
after CONTBUS-DISABLED clears if the card is in the node database. If CONTBUS-DISABLED has
cleared but IMPROPRMVL is still active, inserting a card will clear the IMPROPRMVL alarm.
For more information about Ethernet cards, refer to the Cisco ONS 15310-CL and Cisco ONS 15310-MA
Ethernet Card Software Feature and Configuration Guide.

Clear the CONTBUS-DISABLED Alarm

If the IMPROPRMVL alarm is raised, complete the
Step 1
page
the Cisco ONS 15310-CL and Cisco ONS 15310-MA Procedure Guide.)
Caution
Always use the supplied electrostatic discharge wristband when working with a powered ONS 15310-CL
or ONS 15310-MA.
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
Step 2
for more information or call Cisco TAC (1-800-553-2447) in order to report a Service-Affecting (SA)
problem.

1.7.43 CONTBUS-IO-A

Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
1-40
Default Severity: Critical (CR), Service-Affecting (SA)
SONET Logical Object: EQPT
1-155. (For general information about card installation, refer to the "Install Hardware" chapter in
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
SONET Logical Object: EQPT