1.2.5 Perform a Facility Loopback on a Destination Port
Step 3
Continue with the
Test the Facility Loopback Circuit
Step 1
If the test set is not already sending traffic, send test-set traffic on the loopback circuit.
Step 2
Examine the test traffic received by the test set. Look for errors or any other signal information that the
test set is capable of indicating.
Step 3
If the test set indicates a good circuit, no further testing is necessary with the loopback circuit.
a.
b.
c.
d.
e.
f.
The entire electrical circuit path has now passed its comprehensive series of loopback tests. This circuit
qualifies to carry live traffic.
If the test set indicates a faulty circuit, the problem might be a faulty card or faulty cabling. Continue
Step 4
with the
Test the Electrical Cabling
Replace the suspect cabling (the cables from the test set to the DS-1, DS-3, or EC-1 port) with a cable
Step 1
known to be good.
If a cable known to be good is not available, test the suspect cable with a test set. Remove the suspect
cable from the electrical port and connect the cable to the Tx and Rx terminals of the test set. Run traffic
to determine whether the cable is good or suspect.
Resend test traffic on the loopback circuit with a good cable installed.
Step 2
If the test set indicates a good circuit, the problem is probably the defective cable. Replace the defective
Step 3
cable.
Clear the facility loopback:
Step 4
a.
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
1-12
"Test the Facility Loopback Circuit" procedure on page
Clear the facility loopback:
Double-click the card, then click the appropriate tab:
Maintenance > DS1 > Loopback
Maintenance > DS3 > Loopback
Maintenance > EC1 > Loopback
Choose None from the Loopback Type column for the port being tested.
Choose the appropriate state (IS,AINS; OOS,DSBLD; or OOS,MT) from the Admin State column
for the port being tested.
Click Apply.
Click Yes in the confirmation dialog box.
"Test the Electrical Cabling" procedure on page
Double-click the card and then click the appropriate tab:
Maintenance > DS1 > Loopback
Maintenance > DS3 > Loopback
Maintenance > EC1 > Loopback
Chapter 1
General Troubleshooting