Chapter 1
Error Messages
Table 1-1
Error Messages (continued)
Error Warning
ID
Error Warning Message
EID-2159
Roll not ready for completion.
{0}
EID-2160
Roll not connected.
{0}
EID-2161
Sibling roll not complete.
{0}
EID-2162
Error during roll acknowledgement.
{0}
EID-2163
Cannot cancel roll.
{0}
EID-2164
Roll error.
{0}
WID-2165
The MAC address of node {0} has been changed. All circuits
originating from or dropping at this node will need to be
repaired.
WID-2166
Unable to insert node into the domain as the node is not
initialized.
WID-2167
Insufficient security privilege to perform this action.
WID-2168
Warnings loading{0}. {1}
WID-2169
One or more of the profiles selected do not exist on one or more
of the nodes selected.
WID-2170
The profile list on node {0} is full. Please delete one or more
profiles if you wish to add profile.
{1}
WID-2171
You have been logged out. Click OK to exit CTC.
WID-2172
The CTC CORBA (IIOP) listener port setting of {0} will be
applied on the next CTC restart.
EID-2173
Port unavailable. The desired CTC CORBA (IIOP) listener
port, {0}, is already in use or you do not have permission to
listen on it. Please select an alternate port.
EID-2174
Invalid number entered. Please check it and try again.
78-17235-01
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
Description
The roll is not ready for completion.
Refer to error messge text.
One of the rolls is not completed for the
dual roll. If it is auto roll, it will be
completed when a valid signal is detected.
If it is a manual roll, you must complete the
roll from CTC if Bridge and Roll is
operated from CTC, or from TL1 if Bridge
and Roll is operated from TL1.
Refer to the error message text.
CTC cannot cancel the roll.
CTC encountered a roll error.
Repair the circuits that originate from or
drop at the specified node, with the new
MAC address.
Initialize the node and proceed.
You do not have the previlege to perform
this action.
CTC encountered warnings while loading
the alarm profile import file.
The profile selected does not exist on the
node. Select another profile.
The number of profile that can exist on a
node has reached the limit. To add a profile,
delete any of the existing profiles.
Refer to the warning message text.
The Internet Inter-ORB Protocol (IIOP)
listener port setting for the CTC Common
Object Request Broker Architecture
(CORBA) will be applied on the next CTC
restart.
Select an alternate port, as the current port
is either in use or you do not have enough
permission on it.
You entered an invalid firewall port number.
Try again.