Clear The Hldovrsync Alarm; I-Hitemp - Cisco ONS 15310-CL Troubleshooting Manual

Sonet multiservice platforms
Hide thumbs Also See for ONS 15310-CL:
Table of Contents

Advertisement

Chapter 1
Alarm Troubleshooting
The Holdover Synchronization Mode condition is caused by loss of the primary and second timing
references in the node. Timing reference loss occurs when line coding on the timing input is different
from the configuration on the node, and it often occurs during the selection of a new node reference
clock. The condition clears when primary or second timing is reestablished. After the 24-hour holdover
period expires, timing slips could begin to occur on an ONS 15310-CL or ONS 15310-MA relying on
an internal clock.

Clear the HLDOVRSYNC Alarm

Clear additional alarms that relate to timing, such as:
Step 1
Reestablish a primary and secondary timing source according to local site practice. If none exists, refer
Step 2
to the "Change Node Settings" chapter in the Cisco ONS 15310-CL and Cisco ONS 15310-MA
Procedure Guide for procedures.
Step 3
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
for more information or call Cisco TAC (1 800 553-2447) in order to report a Service-Affecting (SA)
problem.

1.7.111 I-HITEMP

78-17235-01
1.7.96 FRNGSYNC, page 1-67
1.7.97 FSTSYNC, page 1-68
1.7.110 HLDOVRSYNC, page 1-74
1.7.166 MANSWTOINT, page 1-108
1.7.167 MANSWTOPRI, page 1-108
1.7.168 MANSWTOSEC, page 1-108
1.7.228 SWTOPRI, page 1-135
1.7.229 SWTOSEC, page 1-135
1.7.230 SWTOTHIRD, page 1-136
1.7.231 SYNC-FREQ, page 1-136
1.7.232 SYNCPRI, page 1-136
1.7.233 SYNCSEC, page 1-137
1.7.234 SYNCTHIRD, page 1-138
Default Severity: Critical (CR), Service-Affecting (SA)
SONET Logical Object: NE
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
1.7.111 I-HITEMP
1-75

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ons 15310-ma

Table of Contents