1.6.1 Perform a Facility Loopback on a Source-Node Ethernet Port

1.6.1 Perform a Facility Loopback on a Source-Node Ethernet Port
The facility loopback test is performed on the node source port in the network circuit. Completing a
successful facility loopback on this port isolates the port as a possible failure point.
Note
Facility loopbacks require on-site personnel.
Performing a loopback on an in-service circuit is service-affecting.
Caution
Complete the

Create the Facility Loopback on the Source-Node Ethernet Port

Connect a test set to the port you are testing.
Step 1
Note
Use appropriate cabling to attach the Tx and Rx terminals of the test set to the port you are testing. The
Tx and Rx terminals connect to the same port.
Adjust the test set accordingly. (Refer to manufacturer instructions for test-set use.)
Step 2
In CTC node view, double-click the CE100T-8 card to display the card view.
Step 3
Click the Maintenance > Loopback tabs.
Step 4
Choose OOS,MT from the Admin State column for the port being tested. If this is a multiport card,
Step 5
select the appropriate row for the desired port.
Choose Facility from the Loopback Type column for the port being tested. If this is a multiport card,
Step 6
select the appropriate row for the desired port.
Click Apply.
Step 7
Click Yes in the confirmation dialog box.
Step 8
Note
Complete the
Step 9

Test and Clear the Facility Loopback Circuit

If the test set is not already sending traffic, send test traffic on the loopback circuit.
Step 1
Examine the traffic received by the test set. Look for errors or any other signal information that the test
Step 2
set is capable of indicating.
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
1-28
"Create the Facility Loopback on the Source-Node Ethernet Port" procedure on page
For specific procedures to connect, set up, and use the test set equipment, consult the
manufacturer.
It is normal for the
"LPKTERMINAL (CE100T)" condition on page 1-105
loopback setup. The condition clears when you remove the loopback.
"Test and Clear the Facility Loopback Circuit" procedure on page
Chapter 1
General Troubleshooting
to appear during
1-28.
78-17235-01
1-28.