1.7.11 APSCM

1.7.11 APSCM
The APS Channel Mismatch alarm occurs when the ONS 15310-CL or ONS 15310-MA expects a
working channel but receives a protect channel. In many cases, the working and protect channels are
crossed and the protect channel is active. If the fibers are crossed and the working line is active, the alarm
does not occur. The APSCM alarm occurs only on the system when bidirectional protection is used on
OC-N ports in a 1+1 protection group configuration. The APSCM alarm does not occur in an optimized
1+1 protection configuration.
Invisible laser radiation could be emitted from the end of the unterminated fiber cable or connector.
Warning
Do not stare into the beam directly with optical instruments. Viewing the laser output with certain
optical instruments (for example, eye loupes, magnifiers, and microscopes) within a distance of
100 mm could pose an eye hazard. Statement 1056
Use of controls, adjustments, or performing procedures other than those specified could result in
Warning
hazardous radiation exposure. Statement 1057

Clear the APSCM Alarm

Verify that the working-port channel fibers are physically connected directly to the adjoining node
Step 1
working-port channel fibers.
Always use the supplied electrostatic discharge wristband when working with a powered ONS 15310-CL
Caution
or ONS 15310-MA system.
If the fibers are correctly connected, verify that the protection-port channel fibers are physically
Step 2
connected directly to the adjoining node protection-port channel fibers.
Step 3
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
for more information or call Cisco TAC (1 800 553-2447) in order to report a Service-Affecting (SA)
problem.

1.7.12 APSCNMIS

The APSCNMIS alarm is not used in the ONS 15310 platforms in this release. It is reserved for
development.

1.7.13 APSIMP

Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
1-22
Default Severity: Major (MJ), Service-Affecting (SA)
SONET Logical Object: OCN
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
SONET Logical Object: OCN
Chapter 1
Alarm Troubleshooting
78-17235-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ons 15310-ma

Table of Contents