1.7.16 APS-PRIM-FAC

If one end is provisioned for 1+1 protection switching and the other is provisioned for path protection
switching, an APSMM alarm occurs on the ONS 15310-CL or ONS 15310-MA that is provisioned for
1+1 protection switching.

Clear the APSMM Alarm

For the reporting system, in node view verify the protection scheme provisioning by completing the
Step 1
following steps:
a.
b.
Click Edit.
Step 2
Record whether the Bidirectional Switching check box is checked.
Click OK in the Edit Protection Group dialog box.
Step 3
Log into the far-end node and verify that the OC-3 or OC-12 port 1+1 protection group is provisioned.
Step 4
Verify that the Bidirectional Switching check box matches the checked or unchecked condition of the
Step 5
box recorded in
Click Apply.
Step 6
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
Step 7
for more information or call Cisco TAC (1 800 553-2447).
1.7.16 APS-PRIM-FAC
The Optimized 1+1 APS Invalid Primary Section condition occurs on OC-N ports in an optimized 1+1
protection system if there is an APS status switch between the primary and secondary facilities to
identify which port is primary.
APS-PRIM-FAC is an informational condition and does not require troubleshooting. If the APS switch
Note
is related to other alarms, troubleshoot these alarms as necessary using the procedures in this chapter.

Clear the APS-PRIM-FAC Condition

Step 1
This condition clears when the card receives a valid primary section indication (1 or 2). Correct the
selection if necessary.
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
Step 2
for more information or call Cisco TAC (1 800 553-2447).
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
1-24
In node view, click the Provisioning > Protection tabs.
Click the 1+1 protection group configured for the OC-3 or OC-12 ports.
The chosen protection group is the protection group that is optically connected (with data
communication channel [DCC] connectivity) to the far end.
Step
1. If not, change it to match.
Default Severity: Not Alarmed (NA)
Logical Objects: OCN
Chapter 1
Alarm Troubleshooting
78-17235-01