Cisco ONS 15310-CL Troubleshooting Manual page 281

Sonet multiservice platforms
Hide thumbs Also See for ONS 15310-CL:
Table of Contents

Advertisement

Chapter 1
Error Messages
Table 1-1
Error Messages (continued)
Error Warning
ID
Error Warning Message
EID-2025
This feature cannot be used. Verify that each of the endpoints
of this circuit are running software that supports this feature.
EID-2026
Unable to apply {0} request. {1}
EID-2027
Error deleting circuit drop.
EID-2028
Error removing circuit node.
EID-2029
The requested operation is not supported.
EID-2030
Provisioning error.
EID-2031
Error adding node.
EID-2032
Unable to rename circuit. {0}
EID-2033
An error occurred during validation. {0}
EID-2034
Unable to add network circuits:
{0}
EID-2035
The source and destination nodes are not connected.
EID-2036
Cannot delete this {0}.
LAN Access has been disabled on this node and this {0} is
needed to access the node.
EID-2037
Application error. Cannot find attribute for {0}.
EID-2038
Invalid protection operation.
EID-2040
Please select a node first.
EID-2041
No paths are available on this link. Please make another
selection.
EID-2042
This span is not selectable. Only the green spans with an arrow
may be selected.
78-17235-01
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
Description
Refer to the error or warning message text.
For example, this error is generated from
the node view Provisioning> WDM-ANS>
tabs to indicate that the selected ring type is
not supported by the endpoints of the
circuit. Another example is the
Provisioning> VLAN tabs in card view
(Ethernet card only), where it indicates that
the back-end spanning tree protocol (STP)
disabling is not supported.
Error occurred while attempting to switch a
path protection circuit away from a span.
CTC could not delete the circuit drop.
CTC could not remove the circuit node.
The task you are trying to complete is not
supported by CTC.
There was an error during provisioning.
There was an error while adding a node.
CTC could not rename the circuit.
There was an internal error while validating
the user changes after the Apply button was
pressed. This error can occur in the Edit
Circuit dialog box or in the BLSR table in
the shelf view (rare condition).
Refer to the error message text.
Refer to the error message text.
You cannot delete the DCC/GCC link as it
is needed to access the node.
CTC cannot find an attribute for the
specified item.
The protection operation you tried to
execute is invalid.
You must select a node before performing
the task.
You must select a link that has paths
available.
Refer to the error message text.
1-5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ons 15310-ma

Table of Contents