Chapter 1
Alarm Troubleshooting
The Manual Switch To Second Reference condition occurs when the NE timing source is manually
switched to a second timing source.
MANSWTOSEC is an informational condition and does not require troubleshooting.
Note

1.7.169 MANSWTOTHIRD

The Manual Switch To Third Reference condition occurs when the NE timing source is manually
switched to a third timing source.
MANSWTOTHIRD is an informational condition and does not require troubleshooting.
Note

1.7.170 MANUAL-REQ-SPAN

The Manual Switch Request on span condition occurs when a user initiates a Manual Span command to
move traffic from a working span to a protect span. This condition appears on the network view Alarms,
Conditions, and History tabs. The port where the MANUAL SPAN command was applied is marked with
an "M" on the network view detailed circuit map.

Clear the MANUAL-REQ-SPAN Condition

Step 1
Complete the
page
Step 2
If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/techsupport for more information or call Cisco TAC (1 800 553-2447).

1.7.171 MATECLK

78-17235-01
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Objects: EXT-SREF, NE-SREF
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Object: OCN
"Clear an External Switching Command on a Path Protection Span" procedure on
1-153.
Default Severity: Minor (MN) for ONS 15310-MA
SONET Logical Object: EQPT
The Mate Clock alarm occurs when the active CTX2500 cannot detect the clock from the standby
CTX2500.
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0

1.7.169 MANSWTOTHIRD

1-109