Clear The Tim-S Alarm; Tim-V; Clear The Tim-V Alarm; Tptfail (Ce100T) - Cisco ONS 15310-CL Troubleshooting Manual

Sonet multiservice platforms
Hide thumbs Also See for ONS 15310-CL:
Table of Contents

Advertisement

Chapter 1
Alarm Troubleshooting
In Auto mode on the receiving port, the card sets the expected string to the value of the received string.
If the alarm occurs on a port that has been operating with no alarms, the circuit path has changed or
someone entered a new incorrect value into the Current Transmit String field. Complete the following
procedure to clear either problem.
TIM-S also occurs on a port that has previously been operating without alarms if someone switches the
cables or optical fibers that connect the ports. If enabled on the port, the
can be raised downstream and the

Clear the TIM-S Alarm

Step 1
Double-click the 15310-CL-CTX or CTX2500 to display the card view.
For the 15310-CL-CTX, click the Maintenance > EC1 > Path Trace tabs; for the CTX2500, click the
Step 2
Maintenance > Optical > Path Trace tabs.
In the Expected String column, enter the correct string information.
Step 3
Click Apply.
Step 4
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
Step 5
for more information or call Cisco TAC (1 800 553-2447). If the alarm applies to the STSTRM object,
it is Service-Affecting (SA).

1.7.240 TIM-V

The VT Path TIM alarm is raised on VT terminations when the J2 path trace is enabled and is
mismatched with the expected trace string.

Clear the TIM-V Alarm

Complete the
Step 1
Step 2
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
for more information or call Cisco TAC (1 800 553-2447) to report a service-affecting problem.

1.7.241 TPTFAIL (CE100T)

The Transport (TPT) Layer Failure alarm for the CE-100T-8 card indicates a break in the end-to-end
Ethernet link integrity feature of the CE-100T-8 cards. TPTFAIL indicates a far-end condition and not a
problem with the port reporting TPTFAIL.
78-17235-01
Default Severity: Major (MJ), Service-Affecting (SA)
SONET Logical Object: VT-TERM
"Clear the TIM Alarm" procedure on page
Default Severity: Major (MJ), Service-Affecting (SA)
SONET Logical Object: CE100T
"RFI-L" condition on page 1-119
1-139.
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
1.7.240 TIM-V
"AIS-L" condition on page 1-19
can be raised upstream.