1.7.227 SWMTXMOD-WORK

The Switching Matrix Module Failure on Working Slot alarm is raised by the 15310-CL-CTX or
CTX2500 when a logic component internal to the card's cross connect is OOF with a traffic card in the
system. In this case, the alarm is raised against the traffic card slot.

Clear the SWMTXMOD-WORK Alarm

Complete the
Step 1
the controller card. For the LED behavior, see the
section on page
Verify that the reset is complete and error-free and that no new related alarms appear in CTC. A green
Step 2
ACT/SBY LED indicates an active card. An amber ACT/SBY LED indicates a standby card.
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
Step 3
for more information or call Cisco TAC (1 800 553-2447) in order to report a Service-Affecting (SA)
problem.

1.7.228 SWTOPRI

The Synchronization Switch to Primary Reference condition occurs when the ONS 15310-CL or
ONS 15310-MA switches to the primary timing source (reference 1). The system uses three ranked
timing references. The timing references are typically two BITS-level or line-level sources and an
internal reference.
SWTOPRI is an informational condition. It does not require troubleshooting.
Note

1.7.229 SWTOSEC

The Synchronization Switch to Secondary Reference condition occurs when the ONS 15310-CL or
ONS 15310-MA has switched to a secondary timing source (reference 2).

Clear the SWTOSEC Condition

To clear the condition, clear alarms related to failures of the primary source, such as the
Step 1
alarm on page
78-17235-01
Default Severity: Critical (CR), Service-Affecting (SA)
SONET Logical Object: EQPT
"Soft- or Hard-Reset an Ethernet or Electrical Card in CTC" procedure on page 1-154
1-148.
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Objects: EXT-SREF, NE-SREF
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Objects: EXT-SREF, NE-SREF
1-136.
"1.9.2 Typical Card LED Activity During Reset"
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0