1.7.109 HI-TXPOWER

1.7.109 HI-TXPOWER
The Equipment High Transmit Power alarm is an indicator on the OC-N port transmitted optical signal
power. HI-TXPOWER occurs when the measured optical power of the transmitted signal exceeds the
threshold.
For information about this alarm that applies to DWDM objects, refer to the "Alarm Troubleshooting"
Note
chapter in the Cisco ONS 15454 DWDM Troubleshooting Guide.

Clear the HI-TXPOWER Alarm

In node view, display the card view for the controller card (15310-CL-CTX or CTX2500).
Step 1
Click the Provisioning > Optical > Optics Thresholds tabs.
Step 2
Decrease (change toward the negative direction) the OPT-HIGH column value by 1%.
Step 3
If the card transmit power setting cannot be lowered without disrupting the signal, complete the
Step 4
"Physically Replace a Card" procedure on page
Removing a card that currently carries traffic on one or more ports can cause a traffic hit. To avoid this,
Caution
perform an external switch if a switch has not already occurred. See the
Lock Initiation, and Clearing" section on page 1-148
Always use the supplied electrostatic discharge wristband when working with a powered ONS 15310-CL
Caution
or ONS 15310-MA.
Note
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
Step 5
for more information or call Cisco TAC (1 800 553-2447).

1.7.110 HLDOVRSYNC

Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
1-74
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
SONET Logical Objects: EQPT, OCN
DWDM Logical Object: PPM
When you replace a card with the identical type of card, you do not need to make any changes
to the database.
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Object: NE-SREF
Chapter 1
1-155.
"1.10.1 Protection Switching,
for commonly used traffic-switching procedures.
Alarm Troubleshooting