Ext; Clear The Ext Alarm; Extra-Traf-Preempt; Failtosw - Cisco ONS 15310-CL Troubleshooting Manual

Sonet multiservice platforms
Hide thumbs Also See for ONS 15310-CL:
Table of Contents

Advertisement

Chapter 1
Alarm Troubleshooting
Step 2
If the port has the correct flow rate and duplex setting, troubleshoot the network device connected to the
node and the network management LAN.
Step 3
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
for more information or call Cisco TAC (1 800 553-2447).

1.7.67 EXT

A Failure Detected External to the NE alarm occurs because an environmental alarm is present. For
example, a door could be open or flooding could have occurred.

Clear the EXT Alarm

Follow your standard operating procedure to remedy environmental conditions that cause alarms. The
Step 1
alarm clears when the situation is remedied.
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
Step 2
for more information or call Cisco TAC (1 800 553-2447).

1.7.68 EXTRA-TRAF-PREEMPT

The EXTRA-TRAF-PREEMPT alarm is not used in the ONS 15310 platforms in this release. It is
reserved for future development.

1.7.69 FAILTOSW

The Failure to Switch to Protection Facility condition occurs when a working or protect optical facility
switches to its companion port by using a MANUAL command. For example, if you attempt to manually
switch traffic from an unused protect port to an in-service working port, the switch will fail (because
traffic is already present on the working port) and you will see the FAILTOSW condition.

Clear the FAILTOSW Condition

Look up and troubleshoot the higher-priority alarm. Clearing the higher-priority condition frees the port
Step 1
and clears the FAILTOSW.
If the condition does not clear, log into the Technical Support Website at
Step 2
http://www.cisco.com/techsupport for more information or call Cisco TAC (1 800 553-2447).
78-17235-01
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
SONET Logical Object: ENVALRM
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Object: OCN
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
1.7.67 EXT
1-57

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ons 15310-ma

Table of Contents