As-Mt; Clear The As-Mt Condition; As-Mt-Oog - Cisco ONS 15310-CL Troubleshooting Manual

Sonet multiservice platforms
Hide thumbs Also See for ONS 15310-CL:
Table of Contents

Advertisement

1.7.19 AS-MT

If the AS-CMD condition is reported for a card and not an individual port, in node view click the
Step 4
Provisioning > Alarm Profiles > Alarm Behavior tabs.
Step 5
Locate the row number for the reported card slot.
Step 6
Click the Suppress Alarms column check box to deselect the option for the card row.
If the condition is reported for the shelf, cards and other equipment are affected. To clear the alarm,
Step 7
complete the following steps:
a.
b.
c.
If the condition does not clear, log into the Technical Support Website at
Step 8
http://www.cisco.com/techsupport for more information or call Cisco TAC (1 800 553-2447).
1.7.19 AS-MT
The Alarms Suppressed for Maintenance Command condition applies to OC-3, OC-12, and electrical
ports and occurs when a port is placed in the Out-of-Service and Management, Maintenance
(OOS-MA,MT) service state for loopback testing operations.

Clear the AS-MT Condition

Complete the
Step 1
If the condition does not clear, log into the Technical Support Website at
Step 2
http://www.cisco.com/techsupport for more information or call Cisco TAC (1 800 553-2447).

1.7.20 AS-MT-OOG

The Alarms Suppressed on an Out-Of-Group VCAT Member alarm is raised on an STS or VT member
of a virtual concatenated (VCAT) group whenever the member is in the IDLE (AS-MT-OOG)
administrative state. This alarm can be raised when a member is initially added to a group. In IDLE
(AS-MT-OOG) state, all other alarms for the STS or VT are suppressed.
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
1-26
If the Suppress Alarms column check box is checked for a port row, deselect it and click Apply.
If the Suppress Alarms column check box is not checked for a port row, click
View > Go to Previous View.
In node view, click the Provisioning > Alarm Profiles > Alarm Behavior tabs if you have not
already done so.
Click the Suppress Alarms check box located at the bottom of the window to deselect the option.
Click Apply.
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Objects: CE100T, DS1, DS3, EC1, EQPT, OCN
DWDM Logical Objects: PPM, SHELF
"Clear an OC-N Port Facility or Terminal Loopback Circuit" procedure on page
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Objects: STSTRM, VT-TERM
Chapter 1
Alarm Troubleshooting
1-157.