Perform A Facility Loopback On A Destination Port; Create A Facility Loopback Circuit On A Destination Port - Cisco ONS 15310-CL Troubleshooting Manual

Sonet multiservice platforms
Hide thumbs Also See for ONS 15310-CL:
Table of Contents

Advertisement

Chapter 1
General Troubleshooting
d.
e.
f.

1.2.5 Perform a Facility Loopback on a Destination Port

The final facility loopback test is performed on the last port in the circuit— in this case the port in the
destination node. Completing a successful facility loopback on this port isolates the possibility that the
destination-node cabling, card, or LIU is responsible for a faulty circuit.
Performing a loopback on an in-service circuit is allowed but is service-affecting.
Caution
Loopbacks operate only on ports in the OOS,MT administrative state.
Note

Create a Facility Loopback Circuit on a Destination Port

Step 1
Connect an electrical test set to the port you are testing:
a.
b.
c.
Use CTC to create the facility loopback on the port being tested:
Step 2
a.
b.
c.
d.
Note
78-17235-01
Click Yes in the Delete Circuits dialog box.
Confirm that the hairpin circuit is deleted from the Circuits tab list.
Continue with the
"1.2.5 Perform a Facility Loopback on a Destination Port" procedure on
page
1-11.
If you just completed the
"1.2.4 Perform a Hairpin Test on a Destination-Node Port" procedure on
page
1-9, leave the electrical test set connected to the electrical port in the destination node.
If you are starting the current procedure without the electrical test set connected to the electrical
port, use appropriate cabling to attach the Tx and Rx terminals of the electrical test set to the
electrical interface panel.
Adjust the test set accordingly.
In node view, double-click the card where you are performing the loopback, then click the
appropriate tab:
Maintenance > DS1 > Loopback
Maintenance > DS3 > Loopback
Maintenance > EC1 > Loopback
Select Facility from the Loopback Type column for the port being tested. If you are creating a
loopback on a multiport card, select the row appropriate for the desired port.
Click Apply.
Click Yes in the confirmation dialog box.
It is normal for a
1.7.156 LPBKFACILITY (DS1, DS3)
condition to appear during loopback setup. The condition clears when you remove the loopback.
1.2.5 Perform a Facility Loopback on a Destination Port
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
or
1.7.157 LPBKFACILITY (EC1)
1-11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ons 15310-ma

Table of Contents