3.
If refrigerant does not flow freely into system, try starting
engine first before operating air conditioner.
Temperature
Cooling.
Blower Speed Setting: Hi (3 step).
Engine Speed: 1,300 - 1,500 rpm.
When charging refrigerant system with the engine
running;
Always keep refrigerant supply container in
the upright position.
Never open the high side pressure valve.
4.
Open the manifold gauge low side valve and charge
system to standard capacity.
Gauge Dial
High Side Gauge
Low Side Gauge
NOTE:
These standards are for outside temperatures
between 30° - 35°C (86° - 95°F). The gauge
readings may vary for extreme temperature
conditions.
When outside temperature is low, warm the
refrigerant supply container with warm water
not exceeding 40°C (104°F). Do not allow
water to come in contact with the charging
adapter valve handle.
When outside temperature is high, cool off
refrigerant supply container and condenser
to aid the refrigerant charging process.
5.
Close low-pressure side valve.
6.
Shut off engine and close refrigerant supply container
adapter valve. Disconnect manifold gauge hoses from
vehicle.
Electrical System
Page 50
control
switch
setting:
CAUTION
Standard Reading
13 - 20 kg/cm
(185 - 285 psi)
1.5 - 3.5 kg/cm
(21 - 49 psi)
CAUTION
Maximum
2
2
SP001687