Doosan DX60R Shop Manual page 368

Table of Contents

Advertisement

7.
Reconnect the throttle linkage and the stop solenoid
connector (2, Figure 272).
8.
Reconnect the lube oil line (1, Figure 272) and clamp (2,
Figure 272).
9.
Apply ThreeBond Liquid Gasket or equivalent sealant to
the sealing surface of the pump cover. Install the pump
cover and tighten the cover bolts.
10. Reconnect the fuel return lines, fuel supply line and
coolant lines to the fuel injection pump.
11. Reinstall the fuel injection high-pressure lines. Tighten the
nuts to specification. See "Special Torque Chart" on
page -174
When reinstalling a new or repaired fuel injection
pump, it is important to add engine oil to the fuel
injection pump to provide lubrication for initial start-
up. Add 5-7 oz (150-200 cc) of clean engine oil to the
fuel injection pump at the fill plug located in the upper
outside section of the governor housing.
12. If equipped, verify the fuel injection pump insulator (2,
Figure 273) is not damaged. Reinstall the insulator and
intake manifold if previously removed.
13. Reinstall the coolant pump V-pulley (4, Figure 274),
spacer (3, Figure 274) (if equipped) and engine coolant
fan (2, Figure 274).
14. Reinstall the cooling fan V-belt (1, Figure 274). Adjust it as
described in Check and adjust Cooling Fan V-belt on
page 5-21.
15. Reinstall the cooling fan guard (if equipped).
16. Prime the fuel system. See "" on page -40
17. Operate the engine and check for fuel and coolant leaks.
Engine
Page 188
IMPORTANT
Figure 272
Figure 273
Figure 274
SP001693

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

50001

Table of Contents