Starting failure
Symptoms and conditions of failure
Starter does
not rotates
Possible causes
Radiator overcooling
Radiator cooling insufficient
Cooling water low
Water jacket cracked
Fan belt elongated
Thermostat faulty
Improper lubricating oil
Leakage from lubricating oil system
Trochoid pump discharge rate insufficient
Lubricating oil filter clogged
Pressure regulator valve faulty
Lubricating oil low
Crank case excessively lubricated
Engine
Engine stall
Engine
Speed control error
after start up
output low
Starter
Work
Smoke
Smoke
No load
rotates
load
color
O
O
O
O
Noise and
Cooling
Intake
Lubricating oil
Exhaust gas
vibration
water
air
Work
load
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
Fuel
Electrical parts
Corrective Action
O
Replace the thermostat.
Replace the thermostat.
O
Or check the fan belt for
looseness.
Check
the
cooling
O
system for water leakage.
Repair or replace.
O
Adjust the belt tension.
Inspect or replace.
O
Use the proper lubricating oil.
Repair.
Inspect and repair.
O
Clean or replace.
Clean, adjust, or replace.
Fill the proper lubricating oil.
Inspect the engine oil.
Referenced page number
water
SP001434
Page 270