168 Appendix
Table 102: WBM "Configuration of Connection <n>" Page – "Configuration" Group
Parameter
Certification file
Key file
Use websockets
Use compression
Data Protocol
Cache mode
Last Will
(Last Will) Topic
(Last Will) Message
(Last Will) QoS
(Last Will) Retain
Device info
Device status
Standard commands
Manual
Version 1.1.0, valid from FW Version 03.08.07(20)
751-9301 Compact Controller 100
Explanation
Enter the path here to the file encoded in PEM
format that is used for cloud service authentication.
Enter the path to the file encoded in PEM format that
contains the private key for cloud service
authentication.
Here, you can specify whether the connection to the
cloud platform is to be set up using the Websocket
protocol via Port 443.
If this checkbox is not selected, the connection to
the cloud platform is set up using the MQTT protocol
via Port 8883.
Here, you can set whether the data is to be
compressed using GZIP compression.
Here you can select the data protocol.
Specify in which memory the cache for the data
telegrams should be created.
This selection field is only enabled if a correctly
formatted SD card is inserted (more information is
available in Application Note A500920).
You can specify whether a last will message should
be enabled/disabled.
You can specify the topic under which the last will
messages should be sent.
You can enter the message you wish to use as the
last will message.
You can specify the "Quality of Service" (QoS) of the
last will message.
Here, you can set whether the previous last-will
message sent under a topic from the broker is to be
handled as a retained message.
Specify whether a device info message should be
generated that informs the cloud service of the basic
configuration of the controller (more information is
available in the Application Note A500920).
Specify whether device state messages should be
generated that inform the cloud service about
changes in the mode selector switch and the LEDs
(more information is available in the Application
Note A500920).
Specify whether the integrated standard commands
should be supported (list of standard commands is
available in the Application Note A500920).
If the checkbox is disabled, only the commands
defined in the IEC program are supported.