The Wagner Electrostatic Air Spraying System; Pressure Settings For Round Jet Nozzles - WAGNER GM 5000EA Operating Manual

Electrostatic air spray gun for manual operation for flat or round jet nozzles
Table of Contents

Advertisement

EDITION 04/2016
OPERATING MANUAL
5.6

THE WAGNER ELECTROSTATIC AIR SPRAYING SYSTEM

The nozzle range (chapter 13) provided by WAGNER allows optimum coating results for
any application.
General criteria for selection of nozzles
Flat jet
for large-surface parts
Round jet
for smaller delicate parts
Options for infl uencing the jet spray / spray pattern:
Description
Product pressure
Atomizing air pressure
Air regulation
Stop screw product valve
Nozzle sizes
Electrostatics
Air regulation
closed
5.6.1

PRESSURE SETTINGS FOR ROUND JET NOZZLES

There are 4 nozzle sizes, D8, D12, EARV LV and EARV HV available. The air cap and nozzle are
adjusted according to size to each other and may not be exchanged. During the calibration
of the product pressure
be in a central position as shown in the photo.
Pressure setting
Product pressure
Atomizing air pressure
The table contains default values. Depending on the product, conditions and the desired
result diff erent values are possible or necessary.
ORDER NUMBER DOC2344499
and the atomizing air pressure,
Nozzle D8 (small)
0.8 bar to 1.2 bar
2.0 bar to 2.3 bar
Modifi cation
+ or -
+ or -
from open to closed
from open to closed
Flow rate
+ or - or off
Air regulation
opened
B_03266
the air control lever must
Nozzle D12 (large) / EARV
0.8 bar to 1.6 bar
2.3 bar to 3.0 bar
GM 5000EA
31

Advertisement

Table of Contents
loading