CLEANING OF CLOGGED ROUND JET NOZZLES

1. By means of nozzle spanner (2), loosen nozzle
insert (1) by a half turn.
2. Remove the nozzle spanner and briefl y
actuate trigger guard.
3. After cleaning the nozzle, re-tighten the
nozzle insert.
5.4.5

EXCHANGE OF ROUND JET NOZZLE INSERT

1. Remove nozzle insert (1) using nozzle
spanner (2).
2. Fit the new nozzle insert.