Safety Instructions For Staff; Safe Handling Of Wagner Powder Spray Devices; Grounding The Device; Accessories And Spare Parts - WAGNER PEA-C4-HiCoat Translation Of The Original Operating Manual

Automatic powder spray gun
Table of Contents

Advertisement

VERSION 05/2012
OPERATING MANUAL
4.2

SAFETY INSTRUCTIONS FOR STAFF

Always follow the information in these instructions, particularly the general safety
instructions and the warning instructions.
Always follow local regulations concerning occupational safety and accident
prevention.
Under no circumstances may people with pacemakers enter the area where the
high-voltage fi eld between the spray gun and the work piece to be coated builds up!
4.2.1

SAFE HANDLING OF WAGNER POWDER SPRAY DEVICES

Do not point spray guns at people.
Before all work on the device, in the event of work interruptions and functional faults:
- Switch off the energy/compressed air supply.
- Lock spray guns to prevent them actuating.
- Relieve pressure on spray guns and device.
- In the event of functional faults: Identify and correct the problem, proceed as
described in chapter "Elimination of Faults".
4.2.2

GROUNDING THE DEVICE

The electrostatic charge may, in certain cases, give rise to electrostatic charges on the
device. In the event of discharge, this may result in the formation of sparks or fl ames.
Ensure that the device is grounded before each coating process.
Ground the work pieces to be coated.
Ensure that all persons inside the working area are grounded, e.g. by wearing
electrostatically conductive shoes.
The function of grounding cables must be checked regularly (see EN 60204).
4.2.3

ACCESSORIES AND SPARE PARTS

Only use original Wagner powder hose.
ORDER NUMBER DOC 390829
PEA-C4-HiCoat