Modbus Tcp - Tripp Lite NGI-M08POE8-L2 Owner's Manual

Managed industrial gigabit ethernet switch
Table of Contents

Advertisement

6.10 Modbus TCP

Modbus TCP supports different types of data format for reading. The primary four types of them
are:
Data Access Type
Bit access
Physical Discrete
Inputs
Internal Bits or
Physical
Coils
Word access
Physical Input
(16-bit
Registers
access)
Physical Output
Registers
MODBUS Data Map and Information Interpretation of Tripp Lite IE Switches
MODBUS base address of Tripp Lite switches is 1001(decimal) for Function Code 4.
Address Offset
Data Type
System Information
0x0000
1 word
0x0001
16 words
0x0020
16 words
Function
Function Name
Code
2
Read Discrete Inputs
1
Read Coils
4
Read Input Registers
3
Read Holding
Registers
Interpretation
Description
HEX
Vendor ID = 0x0b04
ASCII
Vendor Name = "Tripp Lite"
Word 0 Hi byte = 'T'
Word 0 Lo byte = 'r'
Word 1 Hi byte = 'i'
Word 1 Lo byte = 'p'
Word 2 Hi byte = 'p'
Word 2 Lo byte = ''
Word 3 Hi byte = 'L'
Word 3 Lo byte = 'i'
Word 4 Hi byte = 't'
Word 4 Lo byte = 'e'
Word 5 Hi byte = '\0
Word 5 Lo byte = '\0''
ASCII
Product Name = "NGI-M08POE8-L2"
Word 0 Hi byte = 'N'
Word 0 Lo byte = 'G'
Word 1 Hi byte = 'I'
Word 1 Lo byte = '-'
Word 2 Hi byte = 'M'
Word 2 Lo byte = '0'
Word 3 Hi byte = '3'
Word 3 Lo byte = 'P'
Word 4 Hi byte = 'O'
Word 4 Lo byte = 'E'
Word 5 Hi byte = '8'
Word 5 Lo byte = '-'
Word 6 Hi Byte = 'L'
Word 6 Lo byte = '2'
Word 7 Hi byte = '\0'
173
Note
Not support now
Not support now
Not support now