CHAPTER 2 WIRING
2.1.3.1
Pulse input terminal
 Format: Command pulse/direction, forward/reverse pulse, A/B phase pulse (parameter switch)
 Max. input frequency: 4[MHz] (differential input), 200[kHz] (open collector input)
2
The 90° phase difference 2 signal is the frequency after multiplying by four. It is normally a multiple
of four.
(1) Differential input
Do not use the PPI terminal.
(2) Open collector (24 [V] DC)
Use the PPI terminal.
* The wiring with the host should be 3 m or less.
(3) Open collector output (12 [V] DC)
Use a resistor (470Ω, 1W), without a PPI terminal, and wire as follows.
* The wiring with the host should be 3 m or less.
2-12
Configuration

Pulse Input (PPI, CA, *CA, CB, *CA)

5V
PPI
Line driver
62
CA(CB)
62
*CA(*CB)
Servo amplifier
0V
PPI
DC24V
62
CA(CB)
62
*CA(*CB)
Servo amplifier
470Ω,1W
CA(CB)
DC12V
*CA(*CB)
Resistors (470Ω) may generate heat.
1.5k
1.5k
62
62
Servo amplifier