Pa4_51 To 59 Notch Filter Settings - Fuji Electric ALPHA7 User Manual

Hide thumbs Also See for ALPHA7:
Table of Contents

Advertisement

PA4_51 to 59 Notch filter settings

No.
Name
51
Notch filter 3 frequency
52
Notch filter 3 attenuation
53
Notch filter 3 width
54
Notch filter 4 frequency
55
Notch filter 4 attenuation
56
Notch filter 4 width
57
Notch filter 5 frequency
58
Notch filter 5 attenuation
59
Notch filter 5 width
Notch filter settings are used to suppress machine system resonance.
Resonance points at up to five locations can be suppressed with PA1_71 to PA1_76.
PA4_51 to PA4_59 are not automatically adjusted, even if PA4_51: Automatic notch filter selection = 1
(enabled).
Refer to "PA1_70 to 76
on the setting method.
Setting range
10 to 4000[Hz]
0 to 40 [dB]
0 to 3
10 to 4000[Hz]
0 to 40 [dB]
0 to 3
10 to 4000[Hz]
0 to 40 [dB]
0 to 3
Notch filter settings" in "4.3.2 Description of Each Parameter" for details
Extension Function 2 Setting Parameters
CHAPTER 4 PARAMETER
Default
Change
value
4000
0
2
4000
0
2
4000
0
2
Always
Always
Always
Always
Always
Always
4
Always
Always
Always
4-117