PA2_78 Display transition at warning detection
No.
Name
Display transition at
78
warning detection
Select whether or not a warning sign is displayed at the keypad on the front panel of the amplifier when
a "cooling fan life expiration," "main circuit capacitor life expiration," or "low battery voltage" warning is
detected.
If the replacement timing is drawing near after several years of operation, change this parameter to "1"
to show a warning on the keypad in front of the servo amplifier.

PA2_80 to 85 Parameter in RAM 1 to 6

No.
Name
80
Parameter in RAM 1
81
Parameter in RAM 2
82
Parameter in RAM 3
83
Parameter in RAM 4
84
Parameter in RAM 5
85
Parameter in RAM 6
If you change some parameters frequently, store them in RAM.
With this setting, you can change parameters infinitely.
Parameters that can be stored in RAM are those marked "Always" in the "Change" field.
The parameter stored in RAM is in the default value when the amplifier is turned on.
[Setting example] 1 to 99 = PA1_1 to 99, 101 to 199 = PA2_1 to 99, 201 to 299 = PA3_1 to 99, 301 to
399 = PA4_1 to 99

PA2_86 to 88 Positioning data in RAM 1 to 3

No.
Name
86
Positioning data in RAM1
87
Positioning data in RAM2
88
Positioning data in RAM3
This parameter is enabled only for LS type.
If you change positioning data frequently, store them in RAM.
With this setting, you can change positioning data infinitely.
The positioning data stored in RAM is in the default value when the amplifier is turned on.
Setting range
0: No transition 1: Transition to
warning display
Setting range
0: No designation
1 to 399: Parameter No.
Setting range
0: No designation
1 to 99: Positioning data No.
Extended Function Setting Parameters
CHAPTER 4 PARAMETER
Default
Change
value
0
Power
Default
Change
value
0
Power
Default
Change
value
0
Power
4