PA2_69 Deviation detection overflow value
No.
Name
Deviation detection
69
overflow value
Specify the value for detecting an "Deviation overflow" alarm.
Enter the parameter in a rotation amount of the motor output shaft.
PA2_70 Overload warning value
No.
Name
70
Overload warning value
Specify the output level of the "overload warning (27)" signal that is issued as an output signal (OUT
signal).
Use the signal as a warning of an "overload (OL)" alarm.
Characteristics of the overload warning are specified in "CHAPTER 9 CHARACTERISTICS."
PA2_72 Station number for communications
No.
Name
Station number for
72
communications
Specify the station number when checking the SX bus cable connecting order or performing degraded
operation.
When set to "0", the SX bus station registered in SX-CPU model is automatically assigned.
For other than "0", specify the same as in system definition of the SX-CPU module.
If not matched, operation is disabled as the SX-CPU module will issue the system definition error.
PA2_74 Parameter write protection
No.
Name
74
Parameter write protection 0: Write enable 1: Write protect
Specify parameter write protection.
Enter "1" to prohibit parameter editing. Only this parameter can be changed.
PA2_75 Positioning data write protection
No.
Name
Positioning data write
75
protection
This parameter is enabled only for LS type.
Specify positioning data write protection.
Enter "1" to prohibit positioning data editing.
Setting range
0.1 [rev] to 100.0 [rev]
Setting range
10 [%] to 100 [%]
Setting range
0 to 238
Setting range
Setting range
0: Write enable 1: Write protect
Extended Function Setting Parameters
CHAPTER 4 PARAMETER
Default
Change
value
15.0
Always
Default
Change
value
50
Always
Default value
Change
0
Power
Default
Change
value
0
Always
Default
Change
value
0
Always
4