Sequence I/O - Fuji Electric ALPHA7 User Manual

Hide thumbs Also See for ALPHA7:
Table of Contents

Advertisement

CHAPTER 2 WIRING

2.1.3 Sequence I/O

The wiring connector is not included in the servo amplifier.
Connector kit type: WSK-D36P
2
35
33
31
FFA
29
FFB
27
FFZ
25
23
21
CONT1
19 COMOUT 20
No
12
35
36
33
34
31
32
29
30
27
28
10
9
16
14
13
2-10
Configuration
CA
36
*CA
17
CB
34
*CB
15
32
*FFA
13
30
*FFB
11
28
*FFZ
9
M5
26
-
7
-
24
-
5
22
CONT2
3
COMIN
1
Terminal
symbol
PPI
Pull-up power input for pulse input 12 to 24 [V] DC
CA
Pulse input (for VS type, counter function only)
*CA
Max. input frequency 4 [MHz] (differential) or 200 [kHz] (open collector)
Command pulse/direction, forward/reverse pulse, A/B phase pulse (A/B
CB
phase pulse are the frequency after multiplication by four.)
*CB
FFA
Pulse output (Differential output)
*FFA
The number of output pulses per motor revolution (16 to 4194304) can
FFB
be designated. Or the output pulse division ratio can be designated. The
output is issued in A/B phase pulse.
*FFB
The FFZ and *FFZ terminals are for single revolution single pulse
FFZ
signal.
*FFZ
FZ
Z-phase output (Open collector)
The FZ terminal is for single revolution single pulse signal. The M5
M5
terminal serves as a reference potential.
MON1
Analog monitor voltage output (±10 [V]/0.5 [mA] max.)
MON2
Analog voltage output terminal for meters. Two outputs are provided.
The M5 terminal serves as a reference potential. Resolution: 14 bits
M5
-
18
M5
-
16
MON1
M5
14
MON2
-
12
PPI
M5
10
FZ
-
8
-
OUT1
6
OUT2
CONT5
4
-
CONT3
2
CONT4
Function