CHAPTER 2 WIRING
 Parameter setting
To assign the edit permission response to IQ area (sequence output terminal), specify the
corresponding value ("29") to the output terminal function setting parameter.
 Relevant description
2
For details, refer to "Edit permission: Sequence input signal (Reference value 55)" signal
description.

Data error: Sequence output signal (Reference value 30)

The signal is turned on if the data reading or writing process between the SX controller and servo
amplifier does not proceed correctly.
 Function
The signal is turned on if the data is incorrect (drifting beyond the specification limit) when data
reading or writing process is executed from SX controller.
The data error is turned off when the read or over write command is turned off.
Setting of parameters is not necessary as the signals have been assigned and fixed in IQ area.
 Parameter settings
If assigning data errors to the sequence output terminal, set a value (30) corresponding to the
output terminal function setting parameter.

Address error: Sequence output signal (Reference value 31)

The signal turns ON when unable to start automatic operation due to an address designation or
immediate data error.
This signal is enabled only for LS type.
 Function
When starting automatic operation with an automatic operation (4) signal, the signal turns ON
when unable to start for the following reasons.
 If an address that lies outside the range is specified
 If the immediate data (position, speed) lies outside the range when performing immediate value
operation
 If an attempt is made to start in the detected OT direction while detecting OT
The signal turns OFF when able to start normally with the correct address designation and
immediate data.
 Parameter
To assign the address error to IQ area (sequence output terminal), specify the corresponding
value ("31") to the output terminal function setting parameter.