Multi-Step Speed Selection [X1]: Sequence Input Signal (Reference Value 51); Multi-Step Speed Selection [X2]: Sequence Input Signal (Reference Value 52); Multi-Step Speed Selection [X3]: Sequence Input Signal (Reference Value 53) - Fuji Electric ALPHA7 User Manual

Hide thumbs Also See for ALPHA7:
Table of Contents

Advertisement

Multi-step speed selection [X1]: Sequence input signal (Reference value 51)

Multi-step speed selection [X2]: Sequence input signal (Reference value 52)

Multi-step speed selection [X3]: Sequence input signal (Reference value 53)

The manual feed speed is specified.
This signal is enabled only for LS type.
 Function
The rotation speed while the forward command [FWD] (reverse command [REV]) signal is turned
on is selected.
The motor rotates at the speed selected with multi-step speed [X1], [X2] and [X3].
The setting speed is shown in the table below.
X3
X2
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
 Parameter setting
To assign the multi-step speed selection to IQ area (sequence input terminal), specify the
corresponding value ("51", "52" and "53") to the input terminal function setting parameter.
These signals are handled to be always turned off if they are not assigned to sequence input
terminals.
Parameter
X1
No.
OFF
-
IQ area (word +10, +11)
ON
PA1_41
Manual feed speed 1
OFF
PA1_42
Manual feed speed 2
ON
PA1_43
Manual feed speed 3
OFF
PA1_44
Manual feed speed 4
ON
PA1_45
Manual feed speed 5
OFF
PA1_46
Manual feed speed 6
ON
PA1_47
Manual feed speed 7
CHAPTER 2 WIRING
Rotation speed for enabling
Description of I/O Signals
2
2-71

Advertisement

Table of Contents
loading

Table of Contents