CHAPTER 4 PARAMETER

PA2_12 Reference signal for homing (Deceleration starting signal)

No.
Reference signal for homing
12
(Deceleration starting signal)
If the encoder Z-phase is selected as a reference signal for shift operation, specify the timing signal for
deceleration to the creep speed for homing. The first encoder Z-phase after reference signal for shift
operation detection is the starting point of the home position shift unit amount.
If "Encoder Z-phase" is selected, the speed when homing is started will be homing creep speed, and
the initial encoder Z-phase after starting will be the home position shift amount starting point.
4
Home position LS

PA2_13 Home position LS signal edge selection

No.
Home position LS signal
13
edge selection
Not a compulsory item
Specify the enabling timing of the home position LS signal if the home position LS is specified as a
reference signal for shift operation reference signal for homing (Deceleration starting signal).
Speed
Home
position
LS
4-46
Automatic Operation Setting Parameters
Name
0: Home position LS 1:+OT 2:-OT
3: Encoder Z-phase 5: Stopper
-OT
Home position LS
Homing speed
Speed
OFF
Name
0: Rising edge timing
1: Trailing edge timing
[Home position LS timing selection = 0]
Homing speed
Homing creep speed
OFF
OFF
ON
Setting range
+OT
Homing creep
speed
Time
OFF
ON
Setting range
[Home position LS timing selection = 1]
Speed
Time
Home
OFF
position
LS
Default
Change
value
0
Power
Example where the
home position LS is the
reference signal for
homing
Default
Change
value
0
Power
Homing speed
Homing creep speed
Time
OFF
ON