3.4.6

Reading/writing a Parameter

To read or write a parameter, enter the SEL3, SEL2, SEL1 and SEL0 bits as shown in the table below
and switch the IQ area of the SX bus to that of parameter reading/writing, and designate the page to be
edited (PA*_) and number and set the data.
Reading/writing is executed at the activating edge of the read command or overwrite command.
Data selection (14 word 8 to 11bit)
SEL3
SEL2
SEL1
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
ON
OFF
Address
15
14
13
0
1
2
3
4
5
6
7
OUT3
OUT4
OUT5
8
9
10
11
12
13
14
15
CONT6
CONT7
CONT8
When SEL3, SEL2, SEL1 and SEL0 are updated, CSEL3, CSEL2, CSEL1 and CSEL0 are updated to
the same pattern, indicating that the IQ area is changed.
While the IQ area is the parameter reading/writing area, immediate value positioning and positioning
data operation may not be started. (Operation in progress continues.) In addition, you cannot edit
positioning data or monitor the current value. Speed operation, homing and interrupt positioning can be
executed.
Parameter data
SEL0
0,1 word [Read]
ON
PA1_
OFF
PA2_
ON
PA3_
ON
PA4_
12
11
10
9
Parameter read value
Unused
CSEL3 CSEL2 CSEL1 CSEL0
OUT6
OUT7
OUT8
OUT9
Parameter setting
Unused
Unused
SEL3
SEL2
SEL1
CONT9
CONT10 CONT11 CONT12 CONT13 CONT14 CONT15 CONT16 CONT17 CONT18 CONT19
CHAPTER 3 OPERATION
No./data selection
8,9 word
6 word
[Write]
0 to 7bit [Set]
PA1_
Parameter no.
PA2_
Parameter no.
PA3_
Parameter no.
PA4_
Parameter no.
bit
8
7
6
5
Unused
Unused
Parameter no. [Check]
OUT10 OUT11 OUT12 OUT13 OUT14 OUT15 OUT16
Unused
SEL0
Parameter no. [Set]
Operation with LS Type
14 word
0 to 7bit [Check]
Parameter no.
Parameter no.
Parameter no.
Parameter no.
4
3
2
1
0
Unused
Over write
Read
completion
completion
Unused
Unused
Unused
Write
Read
command
command
3-51