Pa2_14 Home Position Shift Unit Amount; Pa2_15 Deceleration Operation For Creep Speed - Fuji Electric ALPHA7 User Manual

Hide thumbs Also See for ALPHA7:
Table of Contents

Advertisement

PA2_14 Home position shift unit amount

No.
Name
Home position shift unit
14
amount
Specify the distance (traveling amount) from the reference
signal for shift operation to the home position.

PA2_15 Deceleration operation for creep speed

No.
Name
Deceleration operation for
15
creep speed
Not a compulsory item
Specify 1 (reverse rotation enable) to return upon detection of the reference signal for shift operation
during movement at the homing speed in the homing direction after reference signal detection
temporarily to the point ahead of the reference signal for shift operation and move at the creep speed
for homing again in the homing direction after reference signal detection to the position (home position)
the home position shift unit amount away from the reference signal for shift operation.
Accurate homing can be executed only with the reference signal for shift operation without a reference
signal for homing (deceleration starting signal).
(1) Homing speed (homing direction after
reference signal detection)
Reference signal for shift
operation
Speed
Reference signal for
homing
Setting range
0 to 2000000000 [unit amount]
Setting range
0: Reverse rotation is disabled
1: Reverse rotation is enabled
(2) Homing creep speed
(reverse)
Reference signal for shift
operation
(1)Homing speed
+
-
OFF
OFF
ON
ON
Automatic Operation Setting Parameters
CHAPTER 4 PARAMETER
Home position shift unit amount
Home position
(3) Homing creep speed (homing direction
after reference signal detection)
Reference signal for shift
operation
(3) Homing creep speed
Time
(2) Homing creep speed
OFF
OFF
ON
Default
Change
value
1000
Always
Reference signal for
shift operation
Default
Change
value
0
Power
4-47
4

Advertisement

Table of Contents
loading

Table of Contents