5.2 Tuningless Function

5.2.1 What is the Tuningless Function?

With the tuningless function, the servo amplifier adjusts parameters automatically to provide almost the
same response based on the machine model or load fluctuations, eliminating the need to make manual
adjustments.

5.2.2 Setting Parameters

The tuningless function is disabled by default.
To enable this function, change PA4_61: Tuningless function to 1 (Enable), and turn the servo amplifier
power ON again.
No.
Name
PA4_61
Tuningless function
CHAPTER 5 SERVO ADJUSTMENT
Setting range
0: Disable
1: Enable
Default value
Change