CHAPTER 4 PARAMETER
PA3_89 Feedback speed sampling time for monitor
No.
Feedback speed
89
sampling time for
monitor
Specify the feedback speed sampling time for monitor.
The sampling time is for the monitoring function. No effect is caused to the control even if the value is
changed.
PA3_90 Output pulse frequency error
4
No.
Output pulse frequency
90
error
If this parameter is enabled, an alarm is output if the FFA, *FFA, FFB, or *FFB terminal pulse output
exceeds the frequency capable of being output. The alarm display shows a command pulse frequency
error (HF alarm).
4-110
Output Terminal Function Setting Parameters
Name
0: 50 [µs]
3: 400 [µs]
6: 3.2 [ms]
Name
0: Disable
1: Enable
Setting range
1: 100 [µs] 2: 200 [µs],
4: 800 [µs] 5: 1.6 [ms],
7: 6.4 [ms]
Setting range
Default
Change
value
1
Always
Default
Change
value
0
Always