Pa2_09 Reverse Traveling Unit Amount For Homing - Fuji Electric ALPHA7 User Manual

Hide thumbs Also See for ALPHA7:
Table of Contents

Advertisement

CHAPTER 4 PARAMETER

PA2_09 Reverse traveling unit amount for homing

No.
Reverse traveling unit
09
amount for homing
Not a compulsory item
Specify the reverse traveling amount taken in the direction opposite to the starting direction for homing
at the start of homing motion.
If a reference signal for homing (deceleration starting signal) or reference signal for shift operation is
detected during reverse travel, movement toward the homing direction after reference signal detection
begins. Use the setting to reduce the homing time.
4
Use if the stopping position is in the direction opposite to the starting direction for homing and the
maximum distance from the stopping position to the zero position is always known.
The unit amount depends on PA1_06 (numerator 0 of electronic gear) and PA1_07 (denominator of
electronic gear).
If neither the reference signal for homing (deceleration starting signal) nor reference signal for shift
operation is detected during reverse motion, movement in the starting direction for homing begins after
reverse motion by the preset traveling amount.
Homing [ORG]
Home position
reference signal
4-44
Automatic Operation Setting Parameters
Name
0 to 2000000000 [unit amount]
Reverse traveling unit
amount for homing
-OT
Reference signal for
shift operation
+
Homing speed
Speed
-
OFF
ON
OFF
Setting range
Starting direction for homing
Stopping position
+OT
Homing creep speed
OFF
OFF
OFF
ON
ON
Default
Change
value
0
Always
Reference value of reverse
Time
traveling unit amount for
homing