Quick Start Guide

Chapter 4
You can use the WireScope 350 with minimal settings. To do this for link or
channel tests, insert the required Basic Link or Channel Adapters as required in
both the WireScope 350 and DualRemote 350. Then, turn both units on and
calibrate as previously directed. Starting at the Main Menu, press Autotest. This
brings up the Autotest Setup screen.
Press Select Settings Profile. The Select Settings Profile screen is displayed,
enabling you select a stored profile. For our example, select Default Cat 5e.
Click OK to return to the Autotest Setup screen. Connect the WireScope 350
and the DualRemote 350 to the cable to be tested. Then click Start to begin the
test. The Autotest result summary screen is displayed. At this point you can
Save the test data, review Details of the test, or Start a new test by pressing the
named button on the screen as described starting on page 46.
Preparing to Run an Autotest 25