Running a single ended fiber autotest

+
Connect the WireScope 350 and attached Fiber SmartProbe
to one end of the
fiber pair to be tested. Using a fiber patch cable, connect the two fibers at the far
end of the fiber pair in a loopback configuration. After pressing Start Test on
the Fiber Autotest Setup screen, the screen shown below will appear.
The Fiber Autotest screen shows the current state of the fibers connected to the
+
Fiber SmartProbe
. The WireScope 350 constantly monitors these connections
waiting for a valid Single Ended configuration. Once this valid configuration is
detected, the cable connections are drawn and the Start Test button is enabled.
Press Start Test or
to begin the Fiber Autotest. The test will run to
completion and the Fiber Autotest Result screen will be displayed.