Remote Calibration

Chapter 4

Preparing to Run an Autotest

The Autotest is the function users run most frequently. The Autotest function is
designed to provide certification testing of installed cabling.
Before you run the Autotest, however, it is important to verify that you have
properly prepared the WireScope 350 for your certification project.
Before you begin testing, it is necessary to calibrate the WireScope and
DualRemote pair that you will use. Remote calibration is a process that allows
the WireScope to compensate for any slight anomalies in its measurement
hardware or that of the companion DualRemote unit.
Connect the WireScope 350 and DualRemote 350 per either of the
configurations below.
Link
Channel
Probe
Probe
If you are testing link configurations to Category 6 / Class E or higher, Agilent
Technologies recommends that you use the precision calibration cable, as this
produces the most accurate calibration.
From the main menu screen, press Calibration. Follow the instructions to
complete the calibration process.
Precision Calibration
Cable
OR
Preparing to Run an Autotest 23