(1)
When released by RESET input
This operation is the same as normal reset operation. Oscillator stabilization time must be ensured
by reset input.
Main Oscillation circuit
System clock
STOP state
RESET signal
Internal system
reset signal
266
Chapter 9 Clock Generator
Figure 9-13: STOP mode released by RESET input
STOP mode setting
Oscillation circuit stop
Preliminary User's Manual U15839EE1V0UM00
Ensuring elapse of oscillation
stabilization time by RESET