Tandberg Data Magnum 224 Product Manual page 265

Hide thumbs Also See for Magnum 224:
Table of Contents

Advertisement

Table E-1 Library error messages (continued)
Error Message
Set Time Fail
Slot Empty
Slot Full
Software Error
System Error
System Fan
System Timeout
Tape Overflow
Terminated
Unknown Drive
A
2007
UGUST
Description
The library could not set the
time on a USB file or
directory.
The command cannot be
completed because the slot
does not contain a cartridge.
The command cannot be
completed because the slot
already contains a cartridge.
The library has experienced
a fatal microcode error.
The library has experienced
a fatal error.
The library has detected that
the system fan is not
operating properly.
An library operation took
too long.
The robot is full and no
empty slot can be found.
The operation has been
stopped by the user.
The library does not
recognize the tape drive.
M
AGNUM
Corrective Action
1.
Ensure that the USB device is securely
inserted and retry the operation.
2.
Retry with another USB device.
If the error persists, contact Technical Support
(see
page
iii) or your service provider.
Select a slot that has a cartridge and retry the
operation.
Do one of the following:
ƒ Empty the slot and retry the operation.
ƒ Select a slot location that does not contain a
cartridge and retry the operation.
1.
Reset the library and retry the operation. See
page 134
for reset instructions.
2.
If the error persists, contact Technical Support
(see
page
iii) or your service provider.
1.
Reset the library and retry the operation. See
page 134
for reset instructions.
2.
If the error persists, contact Technical Support
(see
page
iii) or your service provider.
1.
Power cycle the library.
2.
If the error persists, contact Technical Support
or your service provider.
1.
Reset the library and retry the operation. See
page 134
for reset instructions.
2.
If the error persists, contact Technical Support
(see
page
iii) or your service provider.
Remove one or more cartridges.
See
"Loading Cartridges into the I/E Port" on
page 116
(to remove a single cartridge).
See
"Loading Cartridges into a Magazine" on
page 120
(to remove multiple cartridges).
Retry the operation, if desired.
1.
Verify that the tape drive settings in the "Drive
Configuration menu match the type of tape
drive(s) installed.
2.
Ensure that you have a valid SCSI ID set for
the tape drive. See
on page
49.
224, S
L
T24,
TORAGE
IBRARY
OR
T
A
F
APE
LERT
LAGS
"Changing the SCSI IDs"
S
L
2U
TORAGE
OADER
247

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storagelibrary t24Storageloader 2u lto