Tandberg Data Magnum 224 Product Manual page 264

Hide thumbs Also See for Magnum 224:
Table of Contents

Advertisement

A
E—E
M
PPENDIX
RROR
ESSAGES
Table E-1 Library error messages (continued)
Error Message
Robot Full
SCSI Error
SCSI Timeout
Sequential Mode
Service Busy
Servo Failure
Servo Jammed
Servo Timeout
Servo Unsafe
Set Date Fail
P
M
RODUCT
ANUAL
246
Description
The robot is unexpectedly
full
An error occurred in the
ADI/SCSI interface.
A timeout occurred in the
ADI/SCSI interface.
The library is set to operate
in Sequential Mode
The library is executing a
command issued from the
backup application when a
command is issued from the
operator panel.
The library's cartridge
handling mechanism (robot)
has experienced a problem.
The library's cartridge
handling mechanism (robot)
is jammed.
The library's cartridge
handling mechanism (robot)
was unable to complete an
operation within a specified
time frame.
The library's cartridge
handling mechanism (robot)
has detected an unsafe
situation for the media.
The library could not set the
date on a USB file or
directory.
Corrective Action
1.
Reset the library and retry the operation. See
page 134
for reset instructions.
2.
If the error persists, contact Technical Support
(see
page
iii) or your service provider.
Check the ADI/SCSI cabling and configuration.
See
"Connecting to SCSI" on page
Check the ADI/SCSI cabling and configuration.
See
"Connecting to SCSI" on page
Change to Random Mode and retry the
operation.
See
"Setting the Library to Operate in Sequential
Mode" on page
55.
Wait until the library has finished its current
operation, and then retry the requested
operation.
1.
Reset the library and retry the operation. See
page 134
for reset instructions.
2.
If the error persists, contact Technical Support
(see
page
iii) or your service provider.
1.
Reset the library and retry the operation. See
page 134
for reset instructions.
2.
If the error persists, contact Technical Support
(see
page
iii) or your service provider.
1.
Reset the library and retry the operation. See
page 134
for reset instructions.
2.
If the error persists, contact Technical Support
(see
page
iii) or your service provider.
1.
Reset the library and retry the operation. See
page 134
for reset instructions.
2.
If the error persists, contact Technical Support
(see
page
iii) or your service provider.
1.
Ensure that the USB device is securely
inserted and retry the operation.
2.
Retry with another USB device.
If the error persists, contact Technical Support
(see
page
iii) or your service provider.
17.
17.
1017472

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storagelibrary t24Storageloader 2u lto