(6) System parameter 63, 64.!Basic type"
Para.
Name
63
Speed command gain
64
Speed command offset
The gain or offset of speed command [NREF] terminal can be adjusted.
)'''r/min
!
*&'(
$ Speed command gain
These gains can be set from #0.10 to #1.50 times in 0.01 step.
Specifying the negative sign can invert the rotational direction.
$ Speed command offset
This can be set from -2000 to 2000 in 1 step. The setting value has no unit. The initial value has been set at factory shipment individually.
Automatic offset adjustment is enable in the trial operation mode by the keypad panel ([
in the system para. 64
(7) System parameter 67 to 73!Basic type, SX bus, monitor 2 of T-link"
Para.
Name
67
Monitor 1 signal assignment
68
Monitor 2 signal assignment
69
Monitor 1 scale
70
Monitor 1 offset
71
Monitor 2 scale
72
Monitor 2 offset
73
Monitor 1, 2 output form
Setting range
#0.10 to #1.50 times (in 0.01 step)
–2000 to 2000 (in 1 step)
Speed
+,&-).
/+,&-'.
"""""""
//////
""
/////
+,'-&.
%&'(
*)'''r/min
Setting range
1: Speed command
3: Torque command
1: Speed command
3: Torque command
#2.0 to #10 [V] (in 0.1 step)
–50 to 50 (in 1 step)
#2.0 to #10 [V] (in 0.1 step)
–50 to 50 (in 1 step)
0: Monitor 1 (two-way deflection) / Monitor 2 (two-way deflection)
1: Monitor 1 (one-way deflection) / Monitor 2 (two-way deflection)
2: Monitor 1 (two-way deflection) / Monitor 2 (one-way deflection)
3: Monitor 1 (one-way deflection) / Monitor 2 (one-way deflection)
Speed command voltage
* : System para. 63 setting
2: Speed feedback
4: Position deviation
2: Speed feedback
4: Position deviation
6-36
Initial value
Change
1.00
Always
(Individual)
Always
]). The value after adjustment will be saved
Initial
value
2
3
7.0
0
6.0
0
0
MHT260a (Engl.)
Change
Always
Always
Always
Always
Always
Always
Power