Speed Data; Timer Data; Status; M Code - Fuji Electric Faldic-a RYS-R Series User Manual

Ac servo system
Table of Contents

Advertisement

(2) Speed data (

As the speed data, set the moving speed up to the stop position data in speed of motor shaft. The setting range is up to the maximum
speed of motor in 0.01 [r/min] step.
(0.00 [r/min] cannot be selected.)

(3) Timer data (

As the timer data, set the timer value after arriving a stop position. The setting range is 0.00 to 999.99 [s] in 0.01 step.

(4) Status (

)
Set various information incidental to positioning data. It can be changed by the ∨ key or ∧ key.
1st digit
Setting contents
Indication
Absolute (ABS)
Incremental (INC)

(5) M code (

)
An M code to output by executing the positioning data can be edited. The setting range is 00 to FF in hexadecimal notation. (An arbitrary
value is specified in 1 step.) Each digit is changeable by the ∨ key or ∧ key.
)
)
3rd and 4th digit
Indication
Setting contents
Data continuation (CO)
Cycle end (CEND)
(Unassigned)
7-18
5th digit
Setting contents
Indication
M code later-output
M code simultaneous output
M code no output
MHT260a (Engl.)