11.2 Control block diagram

The control block diagram for RYS-R type amplifier is shown on the next page.
(1) Override
Validated by allocating the control assign terminals [CONTn] to signals.
Setting value
(2) Manual feed
The speed of manual forward or reverse rotation can be selected by multistep speed selection [X1], [X2] and [X3].
X3
X2
X1
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
See 5.3.1 Forward command [FWD]/Reverse command [REV], and 5.7.3 Override.
Signal name
43
Override valid
44
Override 1
45
Override 2
46
Override 4
47
Override 8
Speed
Speed set by speed command [NREF] terminal
Speed set by basic para. 1
Speed set by basic para. 2
Speed set by basic para. 3
Speed set by basic para. 4
Speed set by basic para. 5
Speed set by basic para. 6
Speed set by basic para. 7
11-10