Cables; Power Supply And Motor Input Cables; Cable Size; Cable Type - Fuji Electric Faldic-a RYS-R Series User Manual

Ac servo system
Table of Contents

Advertisement

10.1 Cables

Power supply and control circuit cables in the internal of the control panels are as follows :

(1) Power supply and motor input cables

(a) Cable size
Input voltage class
Amplifier output
Amplifier type
Conductor
Power supply, motor
sectional
input, ground (earth)
area of cable
Brake
2
[mm
]
Power supply for control
(b) Cable type
(i) 600 [V] class, poly-vinyl insulated cable (JIS C 3307) or
(ii) Poly-vinyl insulated cable "KIV" (JIS C 3316) or
(iii) 600 [V] class, cross-link polyethylene insulated cable "FSCL" (JCS 360)
or equivalent
(2) Control input/output cables for CN1 : + 24 [V], 50 [mA] max.
(a) Size of twisted-pair shielded cable, AWG No.26
Amplifier type
CN1 for VVS, LPS, RPS
Cable
18-core
(b) Cable type
"XEBV" or "XEWV" (The Furukawa Electric Co. , Ltd.) or equivalent
(3) Host interface for CN3
(a) Digital input/output and analog signal cable : Same as (2) above.
(b) T-link, JPCN-1 and SX bus : Specified cables should be applied.
(4) Encoder cables for CN2 (4 [Mbps] serial communication)
Cross-link polyethylene insulated, poly-vinyl sheath cables RMCV-SV type :
Wiring length within
Cable size and pair, core quantities (*)
10 [m]
AWG No.25 / 4-pair and AWG No.23 / 2-core
50 [m]
AWG No.25 / 4-pair and AWG No.17 / 2-core
or optional cable : See 10.8.
(*) AWG : Refer to Remark of 4.3 (2) (d).
[V]
100
[kW]
0.05 to 0.2
RYS□□□S3-
□□□6
500 to 201
1.25
1.25
0.75
CN3 for LPS, RPS
10-core
200
0.03 to 0.4
0.75 to 1.5
2, 3
□□□
300 to 401
751 to 152
202, 302
2
3.5
CN1 for others
13-core
10-3
4, 5
402, 502
5.5
MHT260a (Engl.)