Alarm Reset; History Initialization; Parameter Initialization - Fuji Electric Faldic-a RYS-R Series User Manual

Ac servo system
Table of Contents

Advertisement

(3) Position preset (
The current position of motor can be preset. The following alarm detection can be reset.
・ABS data loss
ENT (1 [s] or more)
Current position is the followings :
(a) [D14] to [D0] input value for RYS□□□S3-RPS type
(b) Station No. of 8, 9 word position for RYS□□□-RSS type
(c) Station No. of +6, +7 word position for RYS□□□S3-RTS type
Position preset cannot be made while the motor is rotating and while on status of the clamping end signal.

(4) Alarm reset (

Resets the alarm detected by the amplifier.
ENT (1 [s] or more)

(5) History initialization (

Deletes the history of alarms detected held by the amplifier.
This history can be monitored by a sequence mode of [
ENT (1 [s] or more)
The alarm history is held even after turning off power.

(6) Parameter initialization (

Initializes the basic para. and system para.
* After initializing, be sure to turn off and on power.
ENT (1 [s] or more)
)
ESC
ESC
)
ESC
)
ESC
)
ESC
ENT
ENT
ESC
ENT
].
ENT
ESC
ENT
ESC
7-20
Preset end
ESC
(Initializing end)
(Initializing end)
MHT260a (Engl.)