(3) Alarm detection
The contents of current alarm can be displayed with codes. When [
When an alarm is detected, the following indication will appear.
Major fault
Indication
Description
System error (SE)
Overcurrent (OC)
Overspeed (OS)
Undervoltage (Lv)
Overvoltage (Hv)
Encoder trouble (Et)
Circuit trouble (Ct)
Memory error (dE)
Fuse blown (Fb)
Combination error (CE)
Resistor heat 2 (rH2)
Encoder communication error (EC)
Cont (Control signal) error (CtE)
Overload (OL)
Remarks : The alarm codes are indicated automatically.
On this indication, if the alarm detection is reset by the control input signal, the initial screen (system para. 89 setting) is
displayed.
Resetting of alarm detection can also be executed in the test running mode.

(4) Alarm history

The last 9 times of alarm detection history can be indicated. The indication can be scrolled by the ∧ key and ∨ key.
ENT (1 [s] or more)
                                   
Alarm history indication (A)
Detected history number (1: latest, 9: oldest)
Remark :
The alarm history can be deleted by the test running mode [
Press the ∧ key and ∨ key simultaneously for 1 [s] or more while alarm detection is indicated to reset the alarm detection.
ENT (1 [s] or more)
ESC
ESC
] is displayed, the alarm history can be displayed.
Minor fault
Indication
Description
Resistor heat (rH)
Deviation excessive (OF)
Amplifier overheat (AH)
Encoder overheat (EH)
Absolute data lost (AL)
Absolute data overflow (AF)
Terminal error (tE)
∧,∨
Alarm code (See (3).)
].
7-7
Alarm code
MHT260a (Engl.)