Speed
Origin return [ORG]
Origin LS [LS]
Encoder Z-phase

Origin return end

Indexing end [WPSET]
(level)
Indexing end [WPSET]
(one shot)
(3) Origin return end (22)
This signal is turned on, when the origin return action has been normally ended. After this, this signal is held on, when the current feedback
position is within the origin detection range (basic para. 66) viewed from the origin return end position (basic para. 76).
If the origin detection range is zero, this signal is always on after the origin return end.
Origin return end
Note : The origin is the position where the machine has stopped after ended the origin return action, or has executed the position preset.
It is not necessary the position of the No.1 station mumber.
Basic para. 72
ON
OFF
OFF
OFF
OFF
OFF
ON
OFF
Origin
OFF
ON
Basic para. 75
OFF
ON
Origin detection range (basic para. 66)
5-14
Basic para. 77
Basic para. 76
Time
ON
ON
ON
Current position